ha34e/315-4 hax34p/315-4 hax4/310-4
福州天行健provide原厂gea-bock船用压缩机及压缩机零部件
福州天行健节能科技有限公司提供欧美日船舶原装进口品牌零部件
ha single-stage compressors
the ha-system - the best solution for deep-freezing!
special features:
- direct intake with external ventilation
- suction gas intake directly into the compressor
- motor cooled by an integrated ventilation unit
this reduces the compressed gas temperature and thus expands the range of application while at the same time increasing capacity (deep-freeze, r22, r404a). at the same time, the compressor is physically separated from the compressor, with advantages particularly in the case of motor damage.
hax34e/315-4
application refrigeration & ac
compressor refrigeration capacity 4.64 kw
power consumption 3.38 kw
current draw (400 v) 6.66 a
mass flow 0.035 kg/s
at following operating condition:
refrigerant r404a, r507
reference temperature dew point
evaporating temperature -35.0 °c
condensing temperature 40.0 °c
supply frequency 50 hz
voltage 400 v
suction gas temperature 20 °c
subcooling (outside cond.) 0 k
number of cylinders / bore / stroke 4 / 50 mm / 40 mm
displacement 50/60 hz (1450/1740 ¹/min) 27,30 / 32,80 m³/h
voltage 1) 220-240v δ / 380-420v y -3- 50hz
265-290v δ / 440-480v y -3- 60hz
max. working current 2) 17.1 / 9.9 a
max. power consumption 2) 5.8 kw
starting current (rotor blocked) 2) 111.0 / 64.0 a
motor protection int69 g
protection terminal box / ha-fan ip 66 / ip 44
voltage ha-fan 230 v - 1 - 50/60 hz, 38 w
weight 96 kg
max. permissible overpressure (g) (lp/hp) 3) 19 / 28 bar
connection suction line sv 22 mm - 7/8 "
connection discharge line dv 16 mm - 5/8 "
lubrication oil pump
oil type r134a, r404a, r407a/c/f, r448a, r449a, r450a, r513a bocklub e55
oil type r22 bocklub a46
oil charge 1,3 ltr.
dimensions length / bbbbb / height 578 / 303 / 318 mm
scope of supply
semi-hermetic four cylinder reciprocating compressor with drive motor
single-section compressor housing with hermetically integrated electric motor
oil pump
motor is cooled by an integrated ventilator with air deflection hood.
230 v - 1 - 50/60 hz, 38 w, 0,17 a
winding protection with ptc resistor sensors and electronic trigger unit int69 g
115-230 v ac, 50/60 hz, ip00
possibility of connection of oil level controllers esk, traxoil, ac r or carly 4)
oil charge:
ha: bocklub a46
hax: bocklub e55
sight glass
suction and discharge line valve
inert gas charge
4 anti-vibration pads enclosed
accessories
start unloader by means of a ess (electronic soft start), 400 v - 3 - 50/60 hz, ip20 (connection clamps ip00) for installation in switch cabinet
digital capacity regulator dcr14 230 v - 1 - 50/60 hz, ip65
1 digital capacity regulator = 50% residual capacity
cylinder cover prepared for digital capacity regulator
oil sump heater
110-240 v - 1 - 50/60 hz, 50-120 w, ip66
ptc heater self-regulating
usb converter for int69 g diagnose 5)
thermal protection thermostat per cylinder cover 6)
oil pressure safety switch mp55 230 v - 1 - 50/60 hz, ip20 5)
int69 g diagnose 115-230 v ac, 50/60 hz, ip00 (int69 g not applicable)
dp-modbus gateway 115-230 v ac, 50/60 hz, ip00 including adapter cable 5)
modbus-lan gateway 230 v ac, 50/60 hz, ip00 5)
step protection
special voltage and/or frequency (on request)
notes
1) tolerance (± 10%) relates to the mean value of the voltage range. other voltages and current types on request
all data are based on voltage rms values
2) - the stated value for the max. power consumption is valid for the adjusted power supply.
- starting current (rotor blocked):
part winding (pw) motors: winding 1 / winding 1 2
delta/star (δ/y) motors: δ / y
- take account of the max. operating current / max. power consumption for designing fuses, supply lines and safety devices. fuse: consumption category ac3.
3) lp = low pressure
hp = high pressure
4) only with additional adapter possible
5) enclosure
6) mounted